Inclinometer
IN61
|
|



Individually parameterizable: Inclinometer for static applications.
The inclinometers in the IN61 series are used to detect 2-axis inclinations in the measuring range of ±85° or 1-axis inclinations of up to 360° via an acceleration measuring cell. Various parameters can be customized for individual requirements (e.g. via the PACTware software). Thanks to their high robustness, the inclinometers are also ideally suited for outdoor use.Mechanical | |
---|---|
Dimension | 62,6 mm x 71,6 mm x 20 mm |
Connection types |
M12 connector |
Working temperature | -40 °C ... +85 °C |
Protection level |
IP68 IP69k |
Electrical | |
---|---|
Measuring range | 0°...360° / -85°...+85° |
Accuracy | ≤0.05 % / ≤0.1 % |
Interfaces |
Redundant Analog 0...10 V Redundant Analog 4...20 mA |
Power supply |
15...30 V DC |
Analog sensor with integrated IO-Link communication
- Configurable interfaces
- Parameterization via IO-Link
- Redundant / counter-rotating signals possible (1-axis)
- Reset to factory setting
- Center point of the measurement and start and end point for 1-axismeasurement
- Switching the spirit level function on/off
- Settings on the measuring range
- Type of output signals
- Filter settings
- LED display for operating status and FDT/IODD communication and for setting the center point position (spirit level function).
- Temperature range -40°C ... +85°C and protection class IP68 / IP69K.
- Protection against the influence of salt spray and rapid temperature changes.
Product Certificates | ||
---|---|---|
UL CoC USA/ Canada - Inclinometers PDF ∼ 376,8 KB | 02.2025 |
EN |
Accessories

Teach adapter
Adjustment of the measuring range via teach adapterSetting the angle measuring range to clockwise:
- Move sensor to start position
- Press the Teach-GND button until the output < 4 mA / 0.1 V is switched (approx. 1 s)
- Move sensor to end position
- Press the Teach-GND button until the output is switched to 20 mA / 4.9 V (approx. 3 s)
Resetting the angle measuring range:
- Press the Teach-GND button until the output is switched to 12 mA (approx. 6 s)
- The angle measuring range is reset to 360°
IS40 | 05.TX40.1 |

EMC shield terminal
For EMC-compliant installation of the encoder cable.- Mounting on top hat rail
- Shield diameter
8.0000.4G06.0312 (03-12 mm)
- Weight approx. 7.4 g
- Clamp (spring steel, galvanized)
- Foot (spring steel)
8.0000.4G06.0312 |