Push-pull outputs



Push-pull outputs are suitable for count interface cards, electronic counters or PLC inputs. They are available in two versions:

Push-pull:
  • Push-pull with integrated wave impedance adjustment, recommended cable impedance 40 ... 150 Ω
  • Recommended for long cable lengths, high pulse frequencies and output voltages to 30 V
  • With or without inverted (complementary) signals
Push-pull (7272):
  • Universal line driver 5 … 30 V with low-level (max 0.5 V)
  • Recommended for cable lengths up to 30 m
  • With inverted signals

Push-pull without inverted signals
Push-pull with inverted signals

 