Display counters electromechanical
Microcounter K4x and K6x
Data sheets and more: [click here]
|
K 46/47: |
High shock resistance |
| K 66/67: |
Shock and magnetic-field resistant |
|
Shock resistant miniature counters, low power consumption, various models, e.g. for panel-, PCB and base mounting.
Suitable for soldering and wash-down (IP 65).
For kWh applications, medical equipment, alarm systems, battery-powered units, fuel pumps ...
Type of mounting: Panel mount/PCB mount
Count frequency: 10 Hz
Number of digits: 6/7
Versions from 1.5 V up to 24 V DC |
Microcounter K0x and AK0x
Data sheets and more: [click here]
|
K 04 / K 05 / AK 05: |
Number of digits: 4/5 |
| K 06 / K 07 / AK 07: |
Number of digits: 6/7 |
|
Shock resistant miniature counters, low power consumption, various models, e.g. for panel-, PCB and base mounting.
Suitable for soldering and wash-down (IP 65).
For kWh applications, medical equipment, alarm systems, battery-powered units, fuel pumps ...
Type of mounting: Panel/PCB mount
Count frequency: 25 Hz
Versions from 3...24 VDC and from 24...230 VAC |
DIN-Rail Counter SK
Data sheets and more: [click here]
|
SK 06.1: |
Number of digits: 6 |
| SK 07.1: |
Number of digits: 7 |
|
Pulse counter for DIN rail mounting, high shock resistance
Pulse voltage: 12/24 VDC and 24...230 VAC
Count frequency: 25 Hz
Protection: IP 50 front side |
Microcounter W and AW
Data sheets and more: [click here]
 |
W 15 / AW 15: |
Number of digits: 5, Reset: Yes |
| W 16 / AW 16: |
Number of digits: 6 |
| W 17: |
Number of digits: 7 |
|
Miniature pulse counter for OEM applications. Various housing sizes and mounting options.
Protection: IP 41
Type of mounting: Panel/PCB mount
Pulse voltage: 10...24 VDC and 24...230 ADC
Count frequency: 10Hz |
Counter BK, B, MK und E
Data sheets and more: [click here]
|
BK 14 * / BK 16: |
Number of digits: 4/6, Protection IP 41, Count frequency: 25 Hz |
| B 15 * / B 16 */ B 18: |
Number of digits: 5/6/8, Protection: IP 41, Count frequency: Max. 25 Hz.
Can be combined with preset counter, BVa, HVa and MVs 36 series |
| MK 14 ** / MK 16 ** / MK 18: |
Number of digits: 4/6/8, Protection: IP 50 front side , Count frequency: 25 Hz / 10 Hz |
| E 16 **: |
With metal housing, Number of digits: 6, Protection IP 41, Count frequency: 25 Hz |
|
* Reset: Manual
** Reset: Manual and electrical
Rugged counters with up to 8 digits, with or without reset. |
Pneumatic Counter PMK
Data sheets and more: [click here]
 |
PMK 14: |
Number of digits: 4, Protection: IP 41 |
| PMK 16: |
Number of digits: 6, Protection: IP 41 |
| PMK 18: |
Number of digits: 8, Protection: IP 52, without Reset |
|
Pneumatic counters, suitable for Ex hazardous areas, simple application in pneumatic equipment, with or without reset.
Long-life membrane operation; no leakage.
Type of mounting: Panel mount
Power consumption: 1.5-8 bar
Count frequency: 17 Hz
|
Cyclometer display KWH 17
Data sheets and more: [click here]
Pulse and hours run meter (Time meter) HC77 and SHC77
Data sheets and more: [click here]
|
HC 77: |
Type of mounting: Panel mount |
| SHC 77: |
Type of mounting: DIN-rail |
Pulse and hours run meter in one unit.
Number of digits: 7/8
Panel cut-out: DIN 48 x 48 mm
Type of mounting: Panel mount, DIN-rail
Protection: IP 52 front side
Pulse voltage: 10...130 VDC and 20...264 VAC
|
Energy and hour meter (Time meter) HW 66
Data sheets and more: [click here]
 |
HW 66: |
Energy and hour meter in one device. With function indicator! |
Number of digits: 2x6-digits
Time range: h-Counter 0,1 - 99.999,9 h, Kwh-Counter 00000,1 - 99.999,9
Panel cut-out: DIN 48 x 48 mm
Type of mounting: Panel mount
Protection: IP 65 front side
Pulse voltage: 115/230 VAC
New: with MID approval
|