Safety is - not least since the EU Machinery Directive 2006/42/EG - an "integral part of the construction of drives".
When choosing the right encoder for functional safety the principle applies that safety is achieved through the intelligent combination of encoder, controller and actuator.
Sendix SSI absolute encoders, with an additional Sin/Cos incremental output, and Sin/Cos versions of incremental encoders are available with certification.
But safety goes further than this: safe components are characterised by a robust reliable interface and by the ability to cope with high mechanical and electronic loads.
In order to achieve safe incremental information with the encoder, the controller must monitor the validity of the analogue, 90° phase-shifted sine/cosine signals with the help of the function: sin² + cos² = 1
In order to obtain safe information with the encoder regarding the absolute position, the controller counts the incremental pulses and compares the result with the absolute positions also provided by the encoder.
A 100% reliable mechanical connection is required for a safe function in the applications. Suitably sturdy fixing elements can help eliminate the risk of faults.
According to DIN EN 13849-1 and DIN EN 61800-5-2 up to SIL3/PLe/Kat.4 the following safety functions can be implemented with the encoder:
Safety Integrity Level (SIL) EN 62061 |
Probability of dangerous errors per hour (1/h) |
Performance Level (PL) EN ISO 13849-1 |
|---|---|---|
SIL 0 |
≥ 10 -5 to < 10 -6 |
a |
SIL 1 |
≥ 3 x 10 -6 to < 10 -5 |
b |
SIL 1 |
≥ 10 -6 to < 3 x 10 -6 |
c |
SIL 2 |
≥ 10 -7 to < 10 -6 |
d |
SIL 3 |
≥ 10 -8 to < 10 -7 |
e |
Your contact persons about SIL Encoders and functional Safety:
Arnold Hettich (Productmanager)
Dr. Dirk Clemens (Sales Director Germany)